What ISO 14971 Requires
ISO 14971 consulting builds a risk management process and file for medical devices. For 2027 submissions, connect each hazard to its risk control, verification evidence and residual-risk decision. Keep post-production information feeding back into that file; a risk spreadsheet created once cannot show that the process continues after launch.
It applies across the whole device life cycle, including software as a medical device. A common gap is a risk file written once for a submission and never updated from production and post-market information.
What an ISO 14971 Consultant Does
We do the writing with your engineering, quality and regulatory people, because they hold the product knowledge the file depends on.
- Check your current risk file and process against the standard.
- Set up the risk management plan and your risk acceptability criteria.
- Run the hazard analysis workshops and write up the results.
- Trace risk controls to your design controls and verification evidence.
- Connect production and post-market data back into the file.
- Prepare your team to answer auditor questions on it.
What Goes in the Risk Management File
| Clause | What it asks for | What you end up with |
|---|---|---|
| 4. General requirements | Process, responsibilities, competence and a plan | Risk management plan and acceptability criteria |
| 5. Risk analysis | Intended use, hazards and risk estimates | Hazard analysis |
| 6. Risk evaluation | Compare each risk with your criteria | Evaluated risk records |
| 7. Risk control | Choose, apply and verify controls | Controls traced to verification evidence |
| 8. Overall residual risk | Judge the combined remaining risk against the benefits | Overall evaluation and benefit-risk conclusion |
| 9. Risk management review | Confirm the plan was carried out before release | Risk management report |
| 10. Production and post-production | Collect and review information from the field | A feedback process that updates the file |
How It Connects to MDR, FDA and ISO 13485
EU: EN ISO 14971:2019 with Amendment A11:2021 is the harmonized version for the MDR and IVDR. Its annexes show how the standard relates to the regulations' safety and performance requirements.
US: FDA lists ISO 14971:2019 as a recognized consensus standard. FDA's Quality Management System Regulation has incorporated ISO 13485:2016 since 2 February 2026, so risk management across product realization now sits inside the regulation.
ISO 13485: the standard requires documented risk management in product realization, and ISO 14971 is how most manufacturers meet it. See our ISO 13485 consultant page for the wider quality system work.
What ISO 14971 Consulting Costs
ISO 14971 work is part of our ISO 13485 engagement, with preparation from $4,000–$15,000 by company size. For a standalone risk management file, the number of devices and the state of your existing design records drive the effort most, so we quote in writing after scoping.
ISO 14971 Consultant FAQs
Can you get certified to ISO 14971?
Most companies do not hold a separate ISO 14971 certificate. Auditors and notified bodies check your risk management through your ISO 13485 audit and your technical documentation, so that is what we prepare you for.
Which edition of ISO 14971 applies?
ISO 14971:2019 is the current edition. In Europe, EN ISO 14971:2019 with Amendment A11:2021 is the harmonized version for the MDR and IVDR. ISO/TR 24971:2020 gives guidance on applying it.
Does FDA recognize ISO 14971?
Yes. FDA lists ISO 14971:2019 as a recognized consensus standard, so manufacturers can declare conformity to it in premarket submissions.
How is ISO 14971 connected to ISO 13485?
ISO 13485 requires documented risk management across product realization. ISO 14971 is the standard most manufacturers use to meet that requirement, so the two are usually built together.
How much does ISO 14971 consulting cost?
ISO 14971 work is part of our ISO 13485 engagement, with package from $4,000–$15,000 by company size. For a standalone risk management file, we quote in writing after scoping.
Does Avantcert make the conformity decision?
No. We prepare your risk management file and the system around it. A notified body, certification body or regulator makes the decision.